|
|
Thread Tools | Display Modes |
#1
|
|||
|
|||
[fitsbits] which WCS keywords?
I have a question about what world coordinate system (WCS) keywords to
use for some image data that do not fit neatly into any of the three categories listed in "Representations of world coordinates in FITS," Greisen and Calabretta 2002, Astron & Astrophys, volume 395, pp 1061 - 1075 (Paper I). The three image formats for FITS files listed in Table 2 of Paper I a (a) a primary array or IMAGE extension (i.e. a conventional image), (b) a multidimensional array in a BINTABLE column, and (c) a tabulated list of pixels in a BINTABLE. Different keywords are needed for these three cases because keywords for (b) include a column number and keywords for (c) include one or two column numbers. The image format in question is for the Kepler spacecraft. An array of CCD detectors will be used to take of images of a region of the sky. See http://www.kepler.arc.nasa.gov/ Because of the large data volume, most of the data will be discarded; pixel values in a small region around each of the 170,000 or so targets will be returned from the spacecraft to Earth. The (proposed) FITS data format is a BINTABLE extension for each chip, with two columns; one column has the raw pixel values and the other column has the calibrated pixel values. It will not be possible to tell from the data file alone where a given table element is on the CCD; to avoid redundancy the pixel numbers are given in a separate reference table which is identified by a header keyword. If the pixel numbers were in the data file, this would be case (c), a tabulated list of pixels. The keywords for case (c) cannot be used for the Kepler data format, however, because the keywords include the column numbers of the pixel coordinates, and those columns don't exist. It seems to me that case (b) is reasonably close, even though the element at a given row and column is only a single value (1-D array of length 1). The value in each row really is an image, albeit a very small one! The keywords for case (b) include a column number, which in this case would be 1 for the raw data and 2 for the calibrated data. My question is whether I would be stretching the limits of the FITS standard to use the WCS keywords for a "multidimensional array in a BINTABLE column" for Kepler data. If so, is there a more reasonable alternative? One point that I haven't mentioned but may be relevant is that the values of the WCS keywords will be nearly constant over a period of three months (the spacecraft will be rolled 90 degrees every three months). There will be small, predictable shifts and scale changes due to velocity aberration, and such effects as pointing errors and temperature variations could introduce small, unpredictable shifts. Phil |
Thread Tools | |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Thread Starter | Forum | Replies | Last Post |
Robert Foot's mirror matter hypothesis relevant to dark accelerators? Murray 2003.03.30 | Rich Murray | Astronomy Misc | 1 | March 31st 05 10:50 AM |
Robert Foot's mirror matter hypothesis relevant to dark accelerators? Murray 2003.03.30 | Rich Murray | UK Astronomy | 1 | March 31st 05 10:50 AM |
[fitsbits] WCS Paper III MJD-AVG vs. DATE-AVG | Steve Allen | FITS | 1 | October 22nd 04 07:53 PM |
[fitsbits] WCSLIB 3.5 | Mark Calabretta | FITS | 0 | June 28th 04 08:16 AM |
[fitsbits] BLANK keyword misinterpretation | Steve Allen | FITS | 4 | November 21st 03 04:42 PM |